Part Number Manufacturer / Brand Brife Description Part StatusElement TypeTemperature RangeLength - Lead WireConductor TypeTerminal Type
DFRobot WATERPROOF DS18B20 DIGITAL TEMPE ActiveIC-55°C ~ 125°C
-
-
Exposed Lead Wires
SparkFun Electronics TEMP SENSOR WTRPRF DS18B20 11050 ActiveIC-55°C ~ 125°C
-
-
Exposed Lead Wires
Digilent, Inc. THERMOCOUPLE WIRE K-TYPE 1M ActiveK - Type-73°C ~ 482°C3.281' (1m)
-
Wire Terminal
DFRobot WATERPROOF DS18B20 SENSOR KIT Active
-
-10°C ~ 80°C35.43" (900.00mm)3 Conductor System
-
Omron Automation and Safety TEMPERATURE SENSOR ActiveK - Type0 ~ 300°C6.562' (2m)GroundedExposed Lead Wires, Crimping Terminals
Honeywell Sensing and Productivity Solutions TEMP PROBE IMMERSION NTC ActiveThermistor-40°C ~ 150°C
-
-
Connector
Honeywell Sensing and Productivity Solutions TEMP PROBE ActiveThermistor-40 ~ 150°C
-
Non-GroundedConnector
Honeywell Sensing and Productivity Solutions TEMP PROBE ActiveThermistor-40 ~ 150°C
-
Non-GroundedConnector
Honeywell Sensing and Productivity Solutions TEMP PROBE ActiveThermistor-40 ~ 150°C
-
Non-GroundedConnector
Honeywell Sensing and Productivity Solutions TEMP PROBE ActiveThermistor-40 ~ 150°C
-
Non-GroundedConnector
Omron Automation and Safety TEMPERATURE SENSOR ActiveK - Type0 ~ 300°C3.281' (1m)GroundedExposed Lead Wires, Crimping Terminals
Honeywell Sensing and Productivity Solutions TEMP PROBE ActiveThermistor-40 ~ 150°C
-
Non-GroundedConnector
Honeywell Sensing and Productivity Solutions TEMP PROBE IMMERSION NTC ActiveThermistor-40°C ~ 200°C
-
-
Connector
TE Connectivity Measurement Specialties THERMOCOUPLE T-TYPE 350C W-LEADS ActiveT - Type-200°C ~ 350°C
-
-
Exposed Lead Wires
Omron Automation and Safety TEMPERATURE SENSOR ActiveK - Type0 ~ 350°C13.123' (4m)GroundedExposed Lead Wires
Omron Automation and Safety TEMPERATURE SENSOR ActiveK - Type0 ~ 400°C13.123' (4m)GroundedExposed Lead Wires
Omron Automation and Safety TEMPERATURE SENSOR ActiveK - Type0 ~ 400°C6.562' (2m)Non-GroundedExposed Lead Wires
Honeywell Sensing and Productivity Solutions TEMP PROBE AIR/GAS NTC ActiveThermistor-40 ~ 150°C
-
-
Connector
Sensata Technologies TEMP PROBE SS THERMISTOR 12 WIR ActiveThermistor-40°C ~ 125°C12.00" (304.80mm)Non-GroundedConnector
Sensata Technologies TEMP PROBE SS THERMISTOR 12 WIR ActiveThermistor-40°C ~ 125°C12.00" (304.80mm)Non-GroundedConnector
Sensata Technologies TEMP PROBE SS THERMISTOR 12 WIR ActiveThermistor-40°C ~ 125°C12.00" (304.80mm)Non-GroundedConnector
Honeywell Sensing and Productivity Solutions TEMP PROBE AIR/GAS NTC ActiveThermistor-40 ~ 150°C
-
-
Connector
Monnit Corporation ALTA WIRELESS THERMOCOUPLE SENSO ActiveK - Type-100°C ~ 400°C72" (1.83m)
-
-
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA 1M C ActiveK - Type0°C ~ 650°C3.281' (1m)GroundedExposed Lead Wires
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA 1M C ActiveK - Type0°C ~ 650°C3.281' (1m)GroundedExposed Lead Wires
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA .5M ActiveK - Type0°C ~ 650°C16.404' (5m)GroundedExposed Lead Wires
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA .5M ActiveK - Type0°C ~ 650°C16.404' (5m)GroundedExposed Lead Wires
Monnit Corporation ALTA WIRELESS THERMOCOUPLE SENSO ActiveK - Type-100°C ~ 400°C72" (1.83m)
-
-
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA .5M ActiveK - Type0°C ~ 650°C3.281' (1m)GroundedExposed Lead Wires
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA 1M C ActiveK - Type0°C ~ 650°C3.281' (1m)GroundedExposed Lead Wires
Omron Automation and Safety T-COUPLE K L65MM 4M FLANGE ActiveK - Type0 ~ 350°C13.123' (4m)GroundedExposed Lead Wires
Omron Automation and Safety THERMOCOUPLE K ActiveK - Type0 ~ 900°C6.562' (2m)Non-GroundedExposed Lead Wires
Monnit Corporation ALTA WIRELESS THERMOCOUPLE SENSO ActiveK - Type-100°C ~ 400°C5.020' (1.53m)
-
-
Cynergy 3 TEMP PROBE J TYPE 6X200MM 1/4 B ActiveJ - Type0 ~ 1200°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE J TYPE 6X300MM 1/4 B ActiveJ - Type0 ~ 1200°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE J TYPE 6X400MM 1/4 B ActiveJ - Type0 ~ 1200°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X150MM 1/4 B ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X200MM 1/4 B ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X300MM 1/4 B ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X400MM 1/4 B ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE J TYPE 6X200MM 1/4NP ActiveJ - Type0 ~ 1200°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE J TYPE 6X300MM 1/4NP ActiveJ - Type0 ~ 1200°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE J TYPE 6X400MM 1/4NP ActiveJ - Type0 ~ 1200°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X150MM 1/4NP ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X200MM 1/4NP ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X300MM 1/4NP ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Cynergy 3 TEMP PROBE K TYPE 6X400MM 1/4NP ActiveK - Type0 ~ 1350°C
-
Non-GroundedEnclosed Terminals
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA 1M C ActiveK - Type0°C ~ 650°C3.281' (1m)GroundedExposed Lead Wires
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA 1M C ActiveK - Type0°C ~ 650°C3.281' (1m)GroundedExposed Lead Wires
Omron Automation and Safety THERMOCOUPLE K TYPE 1MM DIA 1M C ActiveK - Type0°C ~ 650°C3.281' (1m)GroundedExposed Lead Wires
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9
  10. 10