Part Number Manufacturer / Brand Brife Description Part StatusNumber of ChannelsInputs - Side 1/Side 2Voltage - IsolationCommon Mode Transient Immunity (Min)Input TypeOutput TypeCurrent - Output / ChannelData RatePropagation Delay tpLH / tpHL (Max)Rise / Fall Time (Typ)Voltage - Forward (Vf) (Typ)Current - DC Forward (If) (Max)Voltage - SupplyOperating TemperatureMounting TypePackage / CaseSupplier Device Package
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA15MBd80ns, 80ns3ns, 3ns1.5V10mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA15MBd80ns, 80ns3ns, 3ns1.5V10mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 5KV PUSH PULL SO6L Active11/05000Vrms30kV/µsDCPush-Pull, Totem Pole50mA
-
120ns, 120ns3ns, 3ns1.55V15mA4.5 V ~ 30 V-40°C ~ 110°CSurface Mount6-SOIC (0.295", 7.50mm Width)6-SO
Toshiba Semiconductor and Storage OPTOISO 3.75KV PUSH PULL SO6-5 Active11/03750Vrms10kV/µsDCPush-Pull, Totem Pole10mA20MBd60ns, 60ns15ns, 15ns1.58V20mA4.5 V ~ 5.5 V-40°C ~ 100°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms20kV/µsDCOpen Collector25mA20MBd60ns, 60ns30ns, 30ns1.55V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 5KV PUSH PULL 6DIP GW Active11/05000Vrms10kV/µsDCPush-Pull, Totem Pole25mA5Mbps250ns, 250ns30ns, 30ns1.6V20mA4.5 V ~ 20 V-40°C ~ 100°CSurface Mount6-SOIC (0.268", 6.80mm Width)6-SDIP Gull Wing
Toshiba Semiconductor and Storage OPTOISO 5KV PUSH PULL 6DIP GW Active11/05000Vrms10kV/µsDCPush-Pull, Totem Pole25mA5Mbps250ns, 250ns30ns, 30ns1.6V20mA4.5 V ~ 20 V-40°C ~ 100°CSurface Mount6-SOIC (0.268", 6.80mm Width)6-SDIP Gull Wing
Toshiba Semiconductor and Storage OPTOISO 2.5KV 2CH OPEN COLL 8DIP Active22/02500Vrms200V/µs, 500V/µs (Typ)DCOpen Collector, Schottky Clamped16mA10MBd75ns, 75ns30ns, 30ns1.65V20mA4.5 V ~ 5.5 V-40°C ~ 85°CThrough Hole8-DIP (0.300", 7.62mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL 6MFSOP-5 Active11/03750Vrms15kV/µsAC, DCPush-Pull, Totem Pole25mA5Mbps250ns, 250ns30ns, 30ns1.57V20mA3 V ~ 20 V-40°C ~ 100°CSurface Mount6-SOIC (0.173", 4.40mm Width), 5 Leads6-MFSOP, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 5KV PUSH PULL 6DIP GW Active11/05000Vrms10kV/µsDCPush-Pull, Totem Pole10mA15MBd75ns, 75ns15ns, 15ns1.65V20mA4.5 V ~ 5.5 V-40°C ~ 100°CSurface Mount6-SOIC (0.268", 6.80mm Width)6-SDIP Gull Wing
Toshiba Semiconductor and Storage OPTOISO 2.5KV 2CH OPEN COLL 8SMD Active22/02500Vrms1kV/µsDCOpen Collector, Schottky Clamped16mA10MBd75ns, 75ns30ns, 30ns1.65V20mA4.5 V ~ 5.5 V-40°C ~ 85°CSurface Mount8-SMD, Gull Wing8-SMD
Toshiba Semiconductor and Storage OPTOISO 2.5KV 1CH OPEN COLL 8DIP Active11/02500Vrms200V/µs, 500V/µs (Typ)DCOpen Collector50mA10MBd75ns, 75ns30ns, 30ns1.65V20mA4.5 V ~ 5.5 V0°C ~ 70°CThrough Hole8-DIP (0.300", 7.62mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms15kV/µsDCOpen Collector8mA1Mbps550ns, 400ns
-
1.61V25mA4.5 V ~ 30 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 5KV 2CH OPN COL 8SMD Active22/05000Vrms20kV/µsDCOpen Collector25mA10MBd75ns, 75ns12ns, 3ns1.55V20mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount8-SMD, Gull Wing8-SMD
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6 Active11/03750Vrms15kV/µsDCOpen Collector8mA1Mbps550ns, 400ns
-
1.61V25mA4.5 V ~ 30 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 2.5KV 2CH OPEN COLL 8DIP Active22/02500Vrms1kV/µsDCOpen Collector, Schottky Clamped16mA10MBd75ns, 75ns30ns, 30ns1.65V20mA4.5 V ~ 5.5 V-40°C ~ 85°CThrough Hole8-DIP (0.300", 7.62mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 3.75KV TRI-STATE SO6 Active11/03750Vrms25kV/µsDCTri-State10mA50MBd20ns, 20ns2ns, 1ns1.6V15mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 5KV TRI-STATE SO6L Active11/05000Vrms25kV/µsDCTri-State10mA50MBd20ns, 20ns2ns, 1ns1.6V15mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.295", 7.50mm Width)6-SO
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL 6MFSOP-5 Active11/03750Vrms15kV/µsAC, DCPush-Pull, Totem Pole25mA5Mbps250ns, 250ns30ns, 30ns1.57V20mA3 V ~ 20 V-40°C ~ 100°CSurface Mount6-SOIC (0.173", 4.40mm Width), 5 Leads6-MFSOP, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA15MBd80ns, 80ns3ns, 3ns1.5V10mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms20kV/µsDCOpen Collector25mA20MBd60ns, 60ns30ns, 30ns1.55V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage PHOTOCOUPLER DIP8 THROUGH-HOLE Active11/05000Vrms20kV/µsDCPush-Pull, Totem Pole25mA
-
250ns, 250ns16ns, 14ns1.55V25mA3 V ~ 20 V-40°C ~ 125°CThrough Hole8-DIP (0.300", 7.62mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 5KV 2CH OPN COL 8DIP Active22/05000Vrms20kV/µsDCOpen Collector25mA10MBd75ns, 75ns12ns, 3ns1.55V20mA2.7 V ~ 5.5 V-40°C ~ 125°CThrough Hole8-DIP (0.400", 10.16mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 5KV OPEN COLLECTOR 8DIP Active11/05000Vrms20kV/µsDCOpen Collector50mA15MBd75ns, 75ns3ns, 12ns1.55V20mA2.7 V ~ 5.5 V-40°C ~ 125°CThrough Hole8-DIP (0.300", 7.62mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 3.75KV PUSH PULL SO6-5 Active11/03750Vrms10kV/µsDCPush-Pull, Totem Pole10mA20MBd60ns, 60ns15ns, 15ns1.58V20mA4.5 V ~ 5.5 V-40°C ~ 100°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 5KV OPEN COLL 6DIP GW Active11/05000Vrms20kV/µsDCOpen Collector15mA1Mbps550ns, 400ns
-
1.55V20mA4.5 V ~ 30 V-40°C ~ 125°CSurface Mount6-SOIC (0.268", 6.80mm Width)6-SDIP Gull Wing
Toshiba Semiconductor and Storage OPTOISO 5KV OPEN COLLECTOR 8DIP Active11/05000Vrms20kV/µsDCOpen Collector15mA1Mbps550ns, 400ns
-
1.55V20mA4.5 V ~ 30 V-40°C ~ 125°CThrough Hole8-DIP (0.300", 7.62mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6 Active11/03750Vrms15kV/µsDCOpen Collector8mA1Mbps550ns, 400ns
-
1.61V25mA4.5 V ~ 30 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA20MBd40ns, 40ns15ns, 15ns1.61V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms15kV/µsDCOpen Collector8mA1Mbps550ns, 400ns
-
1.61V25mA4.5 V ~ 30 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage HIGH SPEED LOGIC OUTPUT COUPLER Active11/05000Vrms10kV/µsDCOpen Collector50mA10MBd75ns, 75ns3ns, 12ns1.55V20mA4.5 V ~ 5.5 V-40°C ~ 85°CThrough Hole8-DIP (0.300", 7.62mm)8-DIP
Toshiba Semiconductor and Storage OPTOISO 5KV PUSH PULL SO6L Active11/05000Vrms30kV/µsDCPush-Pull, Totem Pole50mA
-
120ns, 120ns3ns, 3ns1.55V15mA4.5 V ~ 30 V-40°C ~ 110°CSurface Mount6-SOIC (0.295", 7.50mm Width)6-SO
Toshiba Semiconductor and Storage OPTOISO 2.5KV 2CH PUSH PULL 8SO Active22/02500Vrms20kV/µsDCPush-Pull, Totem Pole10mA15MBd80ns, 80ns3ns, 3ns1.5V10mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount8-SOIC (0.154", 3.90mm Width)8-SO
Toshiba Semiconductor and Storage OPTOISO 5KV TRI-STATE S06L Active11/05000Vrms20kV/µsDCPush-Pull, Totem Pole10mA20MBd60ns, 60ns1.3ns, 1ns1.5V8mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.295", 7.50mm Width)6-SO
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms15kV/µsDCOpen Collector8mA1Mbps550ns, 400ns
-
1.61V25mA4.5 V ~ 30 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms20kV/µsDCOpen Collector25mA10MBd100ns, 100ns30ns, 30ns1.55V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA20MBd40ns, 40ns15ns, 15ns1.61V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms15kV/µsDCOpen Collector25mA20Mbps60ns, 60ns30ns, 30ns1.61V25mA4.5 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA15MBd80ns, 80ns3ns, 3ns1.5V10mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms20kV/µsDCOpen Collector25mA10MBd100ns, 100ns30ns, 30ns1.55V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL 6MFSOP-5 Active11/03750Vrms10kV/µsDCPush-Pull, Totem Pole25mA5Mbps250ns, 250ns30ns, 30ns1.57V20mA4.5 V ~ 20 V-40°C ~ 100°CSurface Mount6-SOIC (0.173", 4.40mm Width), 5 Leads6-MFSOP, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA20MBd40ns, 40ns15ns, 15ns1.61V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV PUSH PULL SO6-5 Active11/03750Vrms20kV/µsDCPush-Pull, Totem Pole10mA20MBd40ns, 40ns15ns, 15ns1.61V25mA2.7 V ~ 5.5 V-40°C ~ 125°CSurface Mount6-SOIC (0.179", 4.55mm Width), 5 Leads6-SO, 5 Lead
Toshiba Semiconductor and Storage OPTOISO 3.75KV OPEN COLL SO6-5 Active11/03750Vrms20kV/µsDCOpen Collector25mA10MBd100ns, 100ns30ns, 30ns1.55V25mA2.7 V ~ 5.5 V-40°C ~ 125°C
-
-
-
Toshiba Semiconductor and Storage X36 PB-F PHOTOCOUPLER SO6 ROHS T Active11/03750Vrms25kV/µsDCPush-Pull, Totem Pole25mA
-
250ns, 250ns15ns, 12ns1.55V20mA3 V ~ 20 V-40°C ~ 125°C
-
-
-
Toshiba Semiconductor and Storage 5MBPS COUPLER SO6 ROHS TR Active11/03750Vrms25kV/µsDCPush-Pull, Totem Pole25mA
-
250ns, 250ns15ns, 12ns1.55V20mA3 V ~ 20 V-40°C ~ 125°C
-
-
-
Toshiba Semiconductor and Storage X36 PB-F PHOTOCOUPLER Active11/03750Vrms20kV/µsAC, DCPush-Pull, Totem Pole25mA
-
250ns, 250ns15ns, 12ns1.55V20mA3 V ~ 20 V-40°C ~ 125°C
-
-
-
Toshiba Semiconductor and Storage X36 PB-F PHOTOCOUPLER Active11/03750Vrms20kV/µsAC, DCPush-Pull, Totem Pole25mA
-
250ns, 250ns15ns, 12ns1.55V20mA3 V ~ 20 V-40°C ~ 125°C
-
-
-
Toshiba Semiconductor and Storage 15MBPS HIGH SPEED COUPLER SO6 Active11/03750Vrms20kV/µsAC, DCPush-Pull, Totem Pole10mA15MBd80ns, 80ns3ns, 3ns1.5V10mA2.7 V ~ 5.5 V-40°C ~ 125°C
-
-
-
Toshiba Semiconductor and Storage 15MBPS HIGH SPEED COUPLER VDE Active11/03750Vrms20kV/µsAC, DCPush-Pull, Totem Pole10mA15MBd80ns, 80ns3ns, 3ns1.5V10mA2.7 V ~ 5.5 V-40°C ~ 125°C
-
-
-
  1. 1
  2. 2
  3. 3