HARTING |
SENSOR CURRENT HALL 300A AC |
Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.5% | 15V | 1µs | 25mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
|
HARTING |
SENSOR CURRENT HALL 2000A AC |
Active | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.3% | 15 V ~ 24 V | 1µs | 33mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
|
HARTING |
CURRENT SENSOR HAN OPEN LOOP 300 |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR HAN OPEN LOOP 500 |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR HAN OPEN LOOP 800 |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
SENSOR CURRENT HALL 500A AC |
Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.6% | 15 V ~ 24 V | 1µs | 24mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
|
HARTING |
SENSOR CURRENT HALL 1000A AC |
Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.4% | 15 V ~ 24 V | 1µs | 28mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
|
HARTING |
SENSOR CURRENT HALL 200A AC |
Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 15V | 1µs | 20mA | -40°C ~ 85°C | Bidirectional | Chassis Mount | Module, Single Pass Through |
|
HARTING |
SENSOR CURRENT HALL 200A AC |
Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 12 V ~ 15 V | 1µs | 20mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
|
HARTING |
SENSOR CURRENT HALL 500A AC |
Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±1% | 15 V ~ 24 V | 1µs | 35mA | -40°C ~ 85°C | Bidirectional | Chassis Mount | Module, Single Pass Through |
|
HARTING |
CURRENT SENSOR HAN OPEN LOOP 100 |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR 200A WITH CLAMP T |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR 300A WITH CLAMP T |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR 500A WITH CLAMP T |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR 1000A WITH CLAMP |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR RAILWAY 500A WITH |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR RAILWAY 500A WITH |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
SENSOR CURRENT HALL 1000A AC |
Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.4% | 15 V ~ 24 V | 1µs | 28mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
|
HARTING |
CURRENT SENSOR RAILWAY 500A WITH |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR RAILWAY 1000A WIT |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR RAILWAY 1000A WIT |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
CURRENT SENSOR 2000A WITH CLAMP |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HARTING |
SENSOR CURRENT HALL 2000A AC |
Active | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±0.3% | 15V | 1µs | 33mA | -40°C ~ 85°C | Bidirectional | Chassis Mount | Module, Single Pass Through |
|
HARTING |
CURRENT SENSOR RAILWAY 1000A WIT |
Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |