Schurter Inc. |
LINE FILTER 125/250VAC 4A TH |
Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 4A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 1.6mH |
|
Schurter Inc. |
LINE FILTER 125/250VAC 1A TH |
Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 11mH |
|
Schurter Inc. |
LINE FILTER 125/250VAC 6A TH |
Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 700µH |
|
Schurter Inc. |
LINE FILTER 250VAC 1A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 1A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 1A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 1A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 6A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 12A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 12A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 240VAC 3A |
Active | Single Phase | Two Stage | 48V | 240V | - | - | 3A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 1A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 1A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 3A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 3A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 6A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 10A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 10A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 12A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 12A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC 16A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 16A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 240VAC 6A |
Active | Single Phase | Two Stage | 48V | 240V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC/VDC 1A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 1A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC/VDC 3A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 3A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC/VDC 6A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 250VAC/VDC 10A |
Active | Single Phase | Two Stage | 250V | 250V | - | - | 10A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 240VAC 10A |
Active | Single Phase | Two Stage | 48V | 240V | - | - | 10A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 240VAC 12A |
Active | Single Phase | Two Stage | 48V | 240V | - | - | 12A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 240VAC 15A |
Active | Single Phase | Two Stage | 32V | 240V | - | - | 15A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Spring Cage | - |
|
Schurter Inc. |
LINE FILTER 80VDC 10A CHASS MNT |
Active | DC | Single Stage | 80V | - | - | - | 10A | - | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 200µH |
|
Schurter Inc. |
LINE FILTER 125/250VAC 16A CHASS |
Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 16A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
Schurter Inc. |
LINE FILTER 125/250VAC 20A CHASS |
Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 20A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
Schurter Inc. |
LINE FILTER 125/250VAC 16A CHASS |
Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 16A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
Schurter Inc. |
LINE FILTER 480VAC 10A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 10A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 3mH, L2 - 1.5mH |
|
Schurter Inc. |
LINE FILTER 480VAC 10A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 10A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 3mH, L2 - 1.5mH |
|
Schurter Inc. |
LINE FILTER 480VAC 20A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 20A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.8mH, L2 - 2mH |
|
Schurter Inc. |
LINE FILTER 480VAC 20A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 20A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.8mH, L2 - 2mH |
|
Schurter Inc. |
LINE FILTER 480VAC 50A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 50A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 450µH |
|
Schurter Inc. |
LINE FILTER 480VAC 16A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 16A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 4.5mH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 25A CHASS |
Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 25A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 2.4mH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 30A CHASS |
Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 30A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.9mH, L2 - 10µH |
|
Schurter Inc. |
LINE FILTER 480VAC 36A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 36A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 900µH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 36A CHASS |
Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 36A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1.5mH |
|
Schurter Inc. |
LINE FILTER 480VAC 25A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 25A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 2.4mH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 30A CHASS |
Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 30A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.9mH, L2 - 10µH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 50A CHASS |
Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 50A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH |
|
Schurter Inc. |
LINE FILTER 480VAC 36A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 36A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.5mH, L2 - 2mH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 64A CHASS |
Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 64A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 600µH |
|
Schurter Inc. |
LINE FILTER 125/250VAC 16A CHASS |
Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 16A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 3.5mH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 42A CHASS |
Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 42A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.3mH, L2 - 10µH |
|
Schurter Inc. |
LINE FILTER 480VAC 36A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 36A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.5mH, L2 - 2mH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 42A CHASS |
Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 42A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.3mH, L2 - 10µH |
|
Schurter Inc. |
LINE FILTER 1.2KVDC 100A CHASS |
Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 100A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
Schurter Inc. |
LINE FILTER 480VAC 25A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 25A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 4.5mH |
|
Schurter Inc. |
LINE FILTER 480/520VAC 25A CHASS |
Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 25A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 3mH |
|
Schurter Inc. |
LINE FILTER 480VAC 66A CHASS MNT |
Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 66A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 450µH |
|
Schurter Inc. |
LINE FILTER 125/250VAC 25A CHASS |
Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 25A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 3.5mH |