Número da peça Fabricante / Marca Descrição breve Status da PartePara MediçãoTipo de sensorCurrent - SensingNúmero de canaisSaídaSensibilidadeFreqüênciaLinearidadePrecisãoTensão - FornecimentoTempo de respostaCurrent - Supply (Max)Temperatura de operaçãoPolarizaçãoTipo de montagemPacote / Caso
Tamura SENSOR CURRENT HALL 100A AC/DC ActiveAC/DCHall Effect, Open Loop100A1Ratiometric, Voltage
-
DC ~ 50kHz±0.5%
-
5V5µs15mA-40°C ~ 85°CBidirectionalThrough HoleModule, Single Pass Through
Tamura SENSOR CURRENT FLUX GATE 25A AC ActiveACFlux Gate, Closed Loop25A1Ratiometric, Voltage25mV/A300kHz±1%±1%5V0.3µs35mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT FLUX GATE 15A AC ActiveACFlux Gate, Closed Loop15A1Ratiometric, Voltage41.67mV/A300kHz±1%±1.9%5V0.3µs30mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT FLUX GATE 25A AC ActiveACFlux Gate, Closed Loop25A1Ratiometric, Voltage25mV/A300kHz±1%±1.8%5V0.3µs35mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT FLUX GATE 50A AC ActiveACFlux Gate, Closed Loop50A1Ratiometric, Voltage12.5mV/A300kHz±1%±1.7%5V0.3µs55mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT FLUX GATE 6A AC ActiveACFlux Gate, Closed Loop6A1Ratiometric, Voltage104.2mV/A300kHz±1%±1.7%5V0.3µs25mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT FLUX GATE 15A AC ActiveACFlux Gate, Closed Loop15A1Ratiometric, Voltage41.67mV/A300kHz±1%±1.2%5V0.3µs30mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT FLUX GATE 25A AC ActiveACFlux Gate, Closed Loop25A1Ratiometric, Voltage25mV/A300kHz±1%±1%5V0.3µs35mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT FLUX GATE 50A AC ActiveACFlux Gate, Closed Loop50A1Ratiometric, Voltage12.5mV/A300kHz±1%±0.9%5V0.3µs55mA-40°C ~ 105°CBidirectionalThrough Hole
-
Tamura SENSOR CURRENT HALL 100A AC/DC ActiveAC/DCHall Effect, Closed Loop100A1Ratiometric, Current
-
DC ~ 100kHz±0.15%±0.25%±12 V ~ 15 V0.5µs50mA-40°C ~ 85°CBidirectionalThrough HoleModule
Tamura SENSOR ActiveAC/DCHall Effect, Open Loop300A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
15V5µs20mA-20°C ~ 80°CBidirectionalThrough HoleModule, Single Pass Through
Tamura SENSOR CURRENT HALL 300A AC/DC ActiveAC/DCHall Effect, Open Loop300A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
5V10µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
Tamura SENSOR CURRENT HALL 500A AC/DC ActiveAC/DCHall Effect, Open Loop500A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
5V10µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
Tamura SENSOR CURRENT HALL 800A AC/DC ActiveAC/DCHall Effect, Open Loop800A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
±15V10µs20mA-40°C ~ 85°CBidirectionalPanel MountModule
LEM USA Inc. SENSOR CURRENT HALL 5A AC/DC ActiveAC/DCHall Effect, Open Loop5A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs18mA-10°C ~ 75°CBidirectionalThrough Hole8-DIP Module
LEM USA Inc. SENSOR CURRENT HALL 10A AC/DC ActiveAC/DCHall Effect, Open Loop10A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs18mA-10°C ~ 75°CBidirectionalThrough Hole8-DIP Module
Tamura SENSOR ActiveDCHall Effect, Open Loop150A1Ratiometric, Voltage
-
-
±1%
-
15V3µs20mA-40°C ~ 85°CUnidirectionalChassis MountModule
Tamura SENSOR ActiveDCHall Effect, Open Loop100A1Ratiometric, Voltage
-
-
±1%
-
15V3µs20mA-40°C ~ 85°CUnidirectionalChassis MountModule
Tamura SENSOR ActiveDCHall Effect, Open Loop200A1Ratiometric, Voltage
-
-
±1%
-
15V3µs20mA-40°C ~ 85°CUnidirectionalChassis MountModule
Tamura SENSOR ActiveDCHall Effect, Open Loop300A1Ratiometric, Voltage
-
-
±1%
-
15V3µs20mA-40°C ~ 85°CUnidirectionalChassis MountModule
Tamura SENSOR ActiveDCHall Effect, Open Loop400A1Ratiometric, Voltage
-
-
±1%
-
15V3µs20mA-40°C ~ 85°CUnidirectionalChassis MountModule
Tamura SENSOR ActiveDCHall Effect, Open Loop500A1Ratiometric, Voltage
-
-
±1%
-
15V3µs20mA-40°C ~ 85°CUnidirectionalChassis MountModule
Tamura SENSOR ActiveDCHall Effect, Open Loop600A1Ratiometric, Voltage
-
-
±1%
-
15V3µs20mA-40°C ~ 85°CUnidirectionalChassis MountModule
Tamura SENSOR CURRENT HALL 300A AC/DC ActiveAC/DCHall Effect, Open Loop300A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
5V5µs15mA-40°C ~ 85°CBidirectionalThrough HoleModule, Single Pass Through
Tamura SENSOR CURRENT HALL 600A AC/DC ActiveAC/DCHall Effect, Open Loop600A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
5V5µs15mA-40°C ~ 85°CBidirectionalThrough HoleModule, Single Pass Through
CR Magnetics Inc. SENSOR CURRENT INDICATOR 100A AC ActiveACCurrent Indicator100A1LED2A50Hz ~ 1kHz
-
-
Self Powered
-
-
-10°C ~ 85°CBidirectionalPanel MountModule
LEM USA Inc. SENSOR CURRENT HALL 200A AC/DC ActiveAC/DCHall Effect, Open Loop200A1Ratiometric, Voltage
-
DC ~ 240kHz±0.5%±1%5V3.5µs25mA-40°C ~ 105°CBidirectionalThrough HoleModule
LEM USA Inc. SENSOR CURRENT HALL 400A AC/DC ActiveAC/DCHall Effect, Open Loop400A1Ratiometric, Voltage
-
DC ~ 240kHz±0.5%±1%5V3.5µs25mA-40°C ~ 105°CBidirectionalThrough HoleModule
Tamura SENSOR CURRENT HALL 500A AC/DC ActiveAC/DCHall Effect, Open Loop500A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
5V5µs15mA-40°C ~ 85°CBidirectionalThrough HoleModule, Single Pass Through
Tamura SENSOR CURRENT HALL 700A AC/DC ActiveAC/DCHall Effect, Open Loop700A1Ratiometric, Voltage
-
DC ~ 100kHz±1%
-
5V5µs15mA-40°C ~ 85°CBidirectionalThrough HoleModule, Single Pass Through
Tamura SENSOR CURRENT HALL 100A AC/DC ActiveAC/DCHall Effect, Closed Loop100A1Ratiometric, Current
-
DC ~ 100kHz±0.15%±0.5%±12 V ~ 15 V1µs16mA-40°C ~ 85°CBidirectionalThrough HoleModule
Tamura SENSOR CURRENT HALL 150A AC/DC ActiveAC/DCHall Effect, Closed Loop150A1Ratiometric, Current
-
DC ~ 100kHz±0.25%±0.5%±12 V ~ 15 V1µs16mA-40°C ~ 85°CBidirectionalThrough HoleModule
Tamura SENSOR CURRENT HALL 100A AC/DC ActiveAC/DCHall Effect, Closed Loop100A1Ratiometric, Current
-
DC ~ 100kHz±0.15%±0.5%±12 V ~ 15 V1µs16mA-40°C ~ 85°CBidirectionalThrough HoleModule, Single Pass Through
LEM USA Inc. SENSOR CURRENT HALL 400A AC/DC ActiveAC/DCHall Effect, Open Loop400A1Ratiometric, Voltage
-
DC ~ 50kHz±0.5%±1%5V5µs19mA-40°C ~ 85°CBidirectionalThrough HoleModule
LEM USA Inc. SENSOR CURRENT HALL 50A AC/DC ActiveAC/DCHall Effect, Open Loop50A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±12 V ~ 15 V3µs15mA-40°C ~ 80°CBidirectional
-
Ring Opening 0.630" Dia, 4 Leads
LEM USA Inc. SENSOR CURRENT HALL 100A AC/DC ActiveAC/DCHall Effect, Open Loop100A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±12 V ~ 15 V3µs15mA-40°C ~ 80°CBidirectional
-
Ring Opening 0.630" Dia, 4 Leads
LEM USA Inc. SENSOR CURRENT HALL 50A AC/DC ActiveAC/DCHall Effect, Open Loop50A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
LEM USA Inc. SENSOR CURRENT HALL 100A AC/DC ActiveAC/DCHall Effect, Open Loop100A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
LEM USA Inc. SENSOR CURRENT HALL 200A AC/DC ActiveAC/DCHall Effect, Open Loop200A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
Honeywell Sensing and Productivity Solutions SENSOR CURRENT HALL 90A AC/DC ActiveAC/DCHall Effect, Closed Loop90A1Ratiometric, Current
-
DC ~ 150kHz±0.2%±0.5%±15V1µs10mA0°C ~ 70°CBidirectionalThrough HoleModule, Single Pass Through
LEM USA Inc. SENSOR CURRENT HALL 400A AC/DC ActiveAC/DCHall Effect, Open Loop400A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
LEM USA Inc. SENSOR CURRENT HALL 500A AC/DC ActiveAC/DCHall Effect, Open Loop500A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
Tamura SENSOR CURRENT HALL 200A AC/DC ActiveAC/DCHall Effect, Closed Loop200A1Ratiometric, Current
-
DC ~ 100kHz±0.25%±1%±12 V ~ 15 V1µs16mA-20°C ~ 70°CBidirectionalChassis MountModule
CR Magnetics Inc. SENSOR CURRENT INDICATOR 100A AC ActiveACCurrent Indicator100A1LED2A50Hz ~ 1kHz
-
-
Self Powered
-
-
-10°C ~ 85°CBidirectionalPanel MountModule
LEM USA Inc. SENSOR CURRENT HALL 600A AC/DC ActiveAC/DCHall Effect, Open Loop600A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±1%±15V3µs15mA-10°C ~ 80°CBidirectionalThrough HoleModule
Honeywell Sensing and Productivity Solutions SENSOR CURRENT SWITCH 1A AC/DC ActiveAC/DCCurrent Switch1A1NPN
-
-
-
±0.5%6 V ~ 16 V100µs12mA-25°C ~ 85°CBidirectionalThrough HoleModule, Single Pass Through
LEM USA Inc. SENSOR CURRENT HALL 800A AC/DC ActiveAC/DCHall Effect, Open Loop800A1Ratiometric, Voltage
-
DC ~ 240kHz±0.5%±1%5V3.5µs25mA-40°C ~ 105°CBidirectionalThrough HoleModule
Tamura SENSOR CURRENT HALL 180A AC/DC ActiveAC/DCHall Effect, Closed Loop180A1Ratiometric, Current
-
DC ~ 200kHz±0.3%±1%±12V1µs16mA-30°C ~ 80°CBidirectionalPanel MountModule
Honeywell Sensing and Productivity Solutions SENSOR CURRENT HALL 400A AC/DC ActiveAC/DCHall Effect, Open Loop400A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±2%15V3µs17mA-10°C ~ 80°CBidirectionalChassis MountModule
Honeywell Sensing and Productivity Solutions SENSOR CURRENT HALL 300A AC/DC ActiveAC/DCHall Effect, Open Loop300A1Ratiometric, Voltage
-
DC ~ 50kHz±1%±2%15V3µs17mA-10°C ~ 80°CBidirectionalChassis MountModule